Contact level measurement of liquids and liquid-liquid interfaces without power supply or with radar

BM 26 A

Magnetic bypass level indicator for liquid and liquid-liquid interface applications
- Continuous level indication; no power supply needed
- Measuring range: 0.3…5.5 / 1…18 ft (longer on request)
- Density: 0.48…3 kg/l / 30…187.3 lb/ft3
- -196…+300°C / -321…+570°F; -1…100 psig / -14…1450 psig
BM 26 ADVANCED

Magnetic bypass level indicator with removable float for basic applications with liquids
- Continuous level measurement; no power supply needed
- Measuring range: 0.3…5.3 m / 1…17.4 ft (longer on request)
- Density: 0.58…2 kg/l / 36.2…124.8 lb/ft3
- -40…+300°C / +570°F; -1…40 barg / -14.5…580 psig
BM 26 BASIC

Magnetic bypass level indicator with non-removable float for basic liquid applications
- Continuous level measurement; no power supply needed
- Measuring range: 0.3…5.3 m / 1…17.4 ft (longer on request)
- Density: 0.8…1.19 kg/l / 49.9…68.7 lb/ft3
- -40…+150°C / +302°F; -1…16 barg / -14.5…232 psig
BM 26 KP

Magnetic bypass level indicator made of PP, PVC or PVDF for highly corrosive liquids
- Continuous level indication; no power supply needed
- Measuring range: 0.3…4 m / 1…13 ft (longer on request)
- Density: ≥ 0.80 kg/l / ≥ 49.9 lb/ft3
- -10…+100°C / -14…+210°F; 0…6 barg / 87 psig
BM 26 PTFE

Magnetic bypass level indicator with PTFE lining for aggressive liquids
- Continuous level measurement; no power supply needed
- Measuring range: 0.3…5.5 / 1…18 ft
- Density: 0.48…3 kg/l / 30…187.3 lb/ft3
- -20…+200°C / -4…+392°F; -1…19 barg / -14.5…276 psig
BM 26 F2200

Magnetic bypass level indicator with guided radar (TDR) for liquid level applications
- Continuous, redundant measurement using two measurement principles in one device
- Measuring range: 0.3…5.5 / 1…18 ft (longer on request)
- Density: 0.5…3 kg/l / 31…187 lb/ft3
- -50…+300°C / -58…+570°F; -1…100 barg / -14.5…1450 psig
BM 26 W1010

Magnetic bypass level indicator with radar (FMCW) for liquid applications
- Continuous redundant measurement using two measurement principles in one device
- Measuring range: 0.3…8 m / 1…26.25 ft (longer on request)
- Density: 0.58…1.2 kg/l / 36…74.9 lb/ft3
- -40…+150°C / +302°F; -1…40 barg / -14.5…580 psig
BM 26 W7300

Magnetic bypass level indicator with radar (FMCW) for liquid applications
- Continuous, redundant measurement using two measurement principles in one device
- Measuring range: 0.3…5.4 m / 1…17.7 ft (longer on request)
- Density: 0.5…3 kg/l / 31…187 lb/ft3
- -50…+200°C / -58…+392°F; -1…100 barg / -14.5…1450 psig
Click here to Request A Quote