For all applications with conductive liquids

OPTIFLUX 1050

Electromagnetic flowmeter for basic applications with conductive liquids
- Cost-effective flow measurement of liquids (≥5 μS/cm) up to +120°C / +248°F
- Extra isolation of electronics for use in high humidity areas
- Wafer-style design: DN10…150 / 3/8 …6", max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®, Modbus
OPTIFLUX 1100

Electromagnetic flowmeter for general applications with conductive liquids
- Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤10%)
- -25…+120°C / -13…+248°F
- Wafer-style design: DN10…150 / 3?8…6", max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®
OPTIFLUX 1300

Electromagnetic flowmeter for OEM applications, dosing systems and compact skids
- Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤70%)
- -25…+120°C / -13…+248°F
- Wafer-style design: DN10…150 / 3/8…6", max. PN40 / ASME Cl 300
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
OPTIFLUX 2050

Electromagnetic flowmeter for basic water and wastewater applications
- Liner materials resistant to low concentrated chemicals
- With extra isolation of electronics for use in high humidity areas
- Flange: DN25…1200 / 1…48", max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®, Modbus
OPTIFLUX 2100

Electromagnetic flowmeter for all standard water and wastewater applications
- Chemically resistant liner materials
- Compact version up to IP69, remote version IP68
- Flange: DN25…1200 / 1…48", max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®
OPTIFLUX 2300

Electromagnetic flowmeter for advanced water and wastewater applications
- High accuracy (±0.2%), with CT approvals (OIML R49, MI-001)
- Cost-saving option without grounding rings and other variants (IP68 etc.)
- Flange: DN25…3000 / 1…120", max. PN40 / ASME Cl 300
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
TIDALFLUX 2300

Electromagnetic flowmeter for applications with partially filled pipes
- With integrated capacitive level measurement for flow measurement of water and wastewater (≥10% pipe fill level)
- Accurate (±1%) and cost-saving alternative to open channel systems
- Flange: DN200…1600 / 8…64"
- 3 x 4…20 mA, pulse, HART®, Modbus, PROFINET
WATERFLUX 3050

Electromagnetic flowmeter for basic water applications
- Cost-effective measurement of potable, raw and irrigation water
- Extra isolation of electronics for use in high humidity areas
- Flange: DN25…600 / 1…24", max. PN16 / ASME Cl 150; others on request
- 4…20 mA, pulse, frequency, status, HART®, Modbus
WATERFLUX 3070

Electromagnetic water meter for district metering of potable water and custody transfer (CT) measurement
- Battery- or mains powered, with battery backup option (incl. Modbus)
- Integrated temperature and pressure measurement for leak monitoring
- CT: MI-001, OIML R49 up to DN600 / 24", no inlet/outlet runs needed
- Burial installation possible (IP68)
WATERFLUX 3100

Electromagnetic flowmeter for standard water applications
- From raw water measurement to drinking water metering in distribution networks
- No inlet/outlet runs needed
- Up to DN600 / 24", max. PN16 / ASME Cl 150
- 4…20 mA, pulse, frequency, status, HART®
WATERFLUX 3300

Electromagnetic flowmeter for advanced water applications
- High accuracy (±0.2%) for water consumption metering and distribution networks
- No inlet/outlet runs needed
- CT: MI-001, OIML R49 up to DN600 / 24"
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
POWERFLUX 4030

Electromagnetic flowmeter for nuclear applications
- Designed and tested for industrial nuclear environments
- DN25…1000 / 1…40"; with resistant ETFE or PFA liner materials
- Free of programmable electronic components
- 4…20 mA
OPTIFLUX 4050

Electromagnetic flowmeter for basic applications with abrasive and aggressive liquids
- Chemically resistant liner materials
- With extra isolation of electronics for use in high humidity areas
- Flange: DN2.5…1200 / 1/10…48", max. PN40 / ASME Cl 1500
- 4…20 mA, pulse, frequency, status, HART®, Modbus
FLEXMAG 4050

Electromagnetic flowmeter for single use biopharmaceutical applications
- With gamma sterilisable disposable flow tube
- One transmitter accommodates two flow tube diameters
- Wetted material compliant with ISO 10993 and USP Class VI
- High accuracy (±1% of MV), wide measuring range, no recalibration
OPTIFLUX 4100

Electromagnetic flowmeter for basic applications with abrasive and aggressive liquids
- Chemically resistant, for liquids (>5 μS/cm) with solid content (≤10%)
- Up to +180°C / +356°F
- Flange: DN2.5…1200 / 1/10…48", max. PN40 / ASME Cl 1500
- 4…20 mA, pulse, frequency, status, HART®
OPTIFLUX 4300

Electromagnetic flowmeter for advanced process and custody transfer (CT) applications
- High accuracy (±0.2%), certified for custody transfer
- For low conductivity media (>1 μS/cm) and high solid contents (≤70%)
- Flange: DN2.5…3000 / 1/10…120", max. PN40 / ASME Cl 1500
- 3 x 4…20 mA, HART®,Modbus, FF, Profibus-PA/DP, PROFINET
POWERFLUX 4300

Electromagnetic flowmeter for nuclear applications
- Designed and tested for industrial nuclear environments
- With resistant ETFE or PFA liner materials
- Flange: DN25…1000 / 1…40"
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
POWERFLUX 5030

Electromagnetic flowmeter for nuclear applications
- Designed and tested for industrial nuclear environments
- With high-tech ceramic tube (DN2.5…100 / 1/10…4") for very aggressive and abrasive fluids
- Free of programmable electronic components
- 4…20 mA
OPTIFLUX 5100

Electromagnetic flowmeter for demanding applications with aggressive and abrasive media
- With chemically resistant ceramic tube for liquids with solid content (≤10%)
- Up to +180°C / +356°F
- Flange: DN2.5…300 / 1/10…12", max. PN40 / ASME Cl 300; Wafer: max. DN100 / 4"
- 4…20 mA, pulse, frequency, status, HART®
OPTIFLUX 5300

Electromagnetic flowmeter for advanced process and master meter applications
- Highest accuracy (±0.15%), with ceramic tube for aggressive and abrasive liquids (≤70% solid content) up to +180°C / +356°F
- CT: OIML R117, MI-005 etc.
- Flange: DN2.5…300 / 1/10…12", max. PN40 / ASME Cl 300; Wafer: DN100 / 4"
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
POWERFLUX 5300

Electromagnetic flowmeter for nuclear applications
- Designed and tested for industrial nuclear environments
- With high-tech ceramic tube for very aggressive and abrasive fluids
- Space-saving wafer design: DN2.5…100 / 1/10…4"
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
BATCHFLUX 5500

Electromagnetic flowmeter for volumetric filling systems in the beverage industry
- High accuracy measurement in process batching, filling and dosing of conductive liquids
- With hygienic ceramic tube and sintered electrodes
- 3A certified up to DN25 / 1"
- Frequency output integrated
OPTIFLUX 6050

Electromagnetic flowmeter for basic hygienic applications
- Cost-effective flow measurement in the food sector
- Meter size: DN2.5…150 / 1/10…6" (3A, EHEDG etc.)
- Many hygienic fittings
- 4…20 mA, pulse, frequency, status, HART®, Modbus
OPTIFLUX 6100

Electromagnetic flowmeter for hygienic standard applications
- Reliable dosing and filling in the food sector
- Meter size: DN2.5…150 / 1/10…6"
- Hygienic fittings and certifications
- 4…20 mA, pulse, frequency, status, HART®
OPTIFLUX 6300

Electromagnetic flowmeter for advanced hygienic applications
- High accuracy (±0.2%), for exact dosing or filling in the food sector
- Meter size: DN2.5…150 / 1/10…6" (3A, EHEDG certified)
- Many hygienic fittings
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
OPTIFLUX 7300

Electromagnetic flowmeter for low conductivity liquids (≥0.05 μS/cm)
- Ceramic tube with non-wetted electrodes for extremely adhesive and abrasive media
- Hygienic and vacuum resistant
- Flange or wafer version: DN25…100 / 1…4", max. PN40 / ASME Cl :300
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
Click here to Request A Quote