For conductive or inductive conductivity measurements

SMARTPAT COND 1200

Conductive conductivity sensor for water and wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: G 3/4 (male)
- 0.1…20 mS/cm; Max. +135°C / +275°F
- With stainless steel electrodes and Pt1000 for temperature compensation
SMARTPAT COND 3200

Conductive conductivity sensor for condensate, process, boiler feed or (ultra)pure water
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: G 3/4 (male), 3/4 NPT (male)
- 0.05…1000 μS/cm; Max. +135°C / +275°F
- With stainless steel electrodes and Pt1000 for temperature compensation
SMARTPAT COND 5200

Conductive conductivity sensor for chemicals and industrial wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: G 3/4 (male), 3/4 NPT (male)
- 10 μS…15 mS/cm; Max. +130°C / +266°F
- With graphite electrodes and Pt1000 for temperature compensation
SMARTPAT COND 7200

Conductive conductivity sensor for food, beverage and pharmaceutical applications
- 2-wire loop powered, 4…20 mA/HART®7, for direct connection to a PCS
- Process connection: VARIVENT® N, Tri-Clamp 1-1/2", 2"
- 0.05…1000 μS/cm; Max. +135°C / +275°F
- With stainless steel electrodes (Ra <0.8 μm) and Pt1000 for temperature compensation
OPTISENS COND 1200

Conductive conductivity sensor for water, wastewater, process water or pure water
- For use with analytical transmitter
- Process connection: G 1/2, G 3/4, G1, 3/4 NPT (male)
- 0.05 μS/cm…20 mS/cm; Max. +135°C / +275°F
- With two stainless steel, titanium or graphite electrodes and Pt100 for temperature compensation
OPTISENS COND 7200

Conductive conductivity sensor for food, beverage and pharmaceutical applications
- For use with analytical transmitter
- Process connection: Clamp DN25-40, 1-1/2"
- 0.05…1000 μS/cm; Max. +135°C / +275°F
- With stainless steel electrodes and Pt100 for temperature compensation
OPTISENS IND 1000

Inductive conductivity sensor for water, wastewater and chemical applications
- For use with analytical transmitter
- Process connection: G 1-1/2 (female) and immersion versions
- 1…2000 mS/cm; Max. +100°C / +212°F
- Electrodeless conductivity sensor with Pt1000 for temperature compensation
OPTISENS IND 7000

Inductive conductivity sensor for food and beverage applications
- For use with analytical transmitter
- Process connection: Conical nozzle (DIN 11851) DN50 and DN65, VARIVENT® N, G1-1/2 or G2 (male, non-hygienic)
- 0.5…2000 mS/cm; Max. +125°C / +257°F (for SIP/CIP)
- Sterilisable PEEK sensor (FDA and EC1935/2004 conform) with temperature compensation
Click here to Request A Quote
or call us today at 704-545-4500